Issue
No. 026 | February
16th, 2009
|
|
Summary
|
|
|
|
Bureau
Veritas ADT has completed the testing of the FIRST 3.5GHz WiMAX
Forum Certified product
WiMAX Forum
announced first batch of 3.5GHz WiMAX Forum Certified products.
One of them is certified through Bureau Veritas ADT's assistance.
That is ZTE's base station, ZXMBW B9100(BBU)-R9100(RRU), operating
at 3.4-3.6GHz Frequency Band, 5MHz, 7MHz and 10MHz Bandwidths, TDD
mode (Profile MP09, MP10 and MP12). With ZTE's great cooperation
during testing, Bureau Veritas ADT finalized all the Certification
Process in an efficient way. WiMAX
Forum's news release
Bureau Veritas
ADT's WiMAX service is dedicating to assist our clients in getting
WiMAX Forum Certified Logo and speeding time to market for their
WiMAX products. Our ONE-STOP WiMAX Certification service, including
WiMAX Forum Certification, M-Taiwan, and Worldwide Regulatory, gives
our clients a convenient environment to complete testing. Any interests
in our WiMAX service please feel free visit our website
or contact our sales representatives for further information. We
are pleased to provide consultancy service to you.
top
|
|
New
WiMAX Forum Certification item update during February Orlando Member
Conference
WiMAX Forum
CWG will implement NCT certification test. The test case will be
selected by the end of June 2009 and the certification testing will
be initiated around then with conpliance with CRSL 7.0.0.
top
|
|
New
WiMAX Forum Certification Profile 2.3GHz update during February
Orlando Member Conference
The validation
of two new 2.3GHz certification profiles MP2300T-1 (2.3GHz,8.75MHz)
& MP2300T-2 (2.3GHz,5 & 10MHz) will be performed on October 1st,
2009. And Certification will be initiated around the end of year
2009 / Jan 2010.
top
|
|
WiMAX
Market update during February Orlando Member Conference
WiMAX Regional
offices located in India, Russia, Japan, China, Taiwan & Brazil
have been updating their latest status such as country WiMAX spectrum,
WiMAX implementation information etc, and also Intel, UQ communication
presented their goal and vision of WiMAX products and services respectively.
For detailed information please link to the website: http://www.wimaxforum.org/apps/org/workgroup/marketing/documents.php?folder_id=1630#folder_1630
top
|
|
Bureau
Veritas ADT Certification Center accredited as NCC RCB to launch
NCC Certification Service
Bureau Veritas
CPS Taoyuan Branch Certification Center (formerly ADT Certification
Center) obtained Regulatory Certification Body (RCB) authorized
by Taiwan Accreditation Foundation (TAF) and National Communications
Commission (NCC) to issue Taiwan Low-Power Radio-Frequency Device
(LPD) certificate and Telecommunication Terminal Equipment (TTE)
certificates. Thus, the Certification Center is pleased to announce
that we are qualified to issue NCC certificate, including LPD, Public
Switched Telephone Network (PSTN), and Public Land Mobile Network
(PLMN) from Feb. 13, 2009. read
more
top
|
|
China
modifies the format of Radio Transmission Equipment Type Approval
Code
In order to
accord with the English abbreviation of Ministry of Industry and
Information Technology (MIIT) of the People's Republic of China,
"CMII" shown in the Radio Transmission Equipment Type Approval Code
has been modified to "CMIIT".
The issued "Radio
Transmission Equipment Type Approval Certificate" and its type approval
code corresponding to original type approval code format are still
valid during their specified term.
read more top
|
|
|
|
China
implements testing sample retention of China Compulsory Certification
in testing labs and applicants
In order to
guarantee certification effectiveness, ensure sample's truthfulness
and facilitate the factory inspection and market surveillance, China
Quality Certification Center (CQC) will implement testing sample
retention in testing laboratories. As of March 1st, 2009, products
with lower acceptance within the market surveillance and higher
risk concerns,
- Audio
& Video: Set Top Boxes, DVD Players
- ITE: Switching
Power Supplies, Power Supplies/Chargers
will endure
to the compulsory samples retention.
Testing laboratories
are in charge of sealing and retaining the samples for 2 years after
issuance of the certificates. The samples are returnable to applicant
after 2 years. Applicants shall do their utmost to keep them well
and shall not cease the contention until 6 months after the certificates
are revoked / deregistered. read
more top
|
|
|
|
Implementing
measure of EuP Directive 2005/32/EC for simple STB published in
OJEU
On Feb. 5th,
2009, the ecodesign implementing measure for simple set-top boxes
was published in OJEU (Official Journal of the European Union).
The Regulation (No 107/2009) shall enter into force on the 20th
day following its publication and apply as from one year after entry
into force.
Ecodesign requirements: Power consumption limits of Simple STB
1st stage: One year after this Regulation has come into force
|
Standby
mode
|
Active
mode
|
| Simple
STB |
1.00
W
|
5.00
W
|
| Allowance
for display function in standby |
+1.00
W
|
-
|
| Allowance
for decoding HD signals |
-
|
+3.00
W
|
2. 2nd stage:
Three years after this Regulation has come into force
|
Standby
mode
|
Active
mode
|
| Simple
STB |
0.50
W
|
5.00
W
|
| Allowance
for display function in standby |
+0.50
W
|
-
|
| Allowance
for hard disk |
-
|
+6.00
W
|
| Allowance
for second tuner |
-
|
+1.00
W
|
| Allowance
for decoding HD signals |
-
|
+1.00
W
|
read